Chlorine Dioxide System Bello Zon CDVd
2.5 – 2,000 g/h chlorine dioxide. Maximum volume of water that can be treated with metering of 0.2 ppm ClO2, depending on the size of the system: 50 - 10,000 m3/h
Chlorine dioxide system for the metering of chlorine dioxide with diluted starting chemicals. The certified yield guarantees efficient chlorine dioxide production. Bello Zon CDVd can be easily and safely integrated into any water treatment process.
Product description
Chlorine dioxide system Bello Zon CDVd is for the treatment of medium to large volumes of water with diluted chemicals.
The CDVd chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system is very user-friendly. The system control features intuitive menu navigation and ensures precise chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary production. The special reactor design produces chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary safely and easily. You benefit from maximum yield with minimal chemical consumption and maximum safety. Communication via common bus systems and our DULCOnneX Platform meets all requirements for tomorrow’s Industry 4.0 standards.
Furthermore, in terms of construction and operation, the system meets all requirements of DVGW Worksheets W 224 and W 624 and is intended for use with diluted chemicals: Bello Zon chlorite (7.5% NaClO2) and acid (9% HCl). The liquid levels of the input chemicals can be displayed and monitored either using external liquid level sensors or via the patent-pending adaptive level monitoring system. CDVd is validated in accordance with the current DIN EN 18087:2026-03 standard.
Your benefits
- Highest operating safety and purity of the ClO2 produced
- Communication interfaces via bus systems and DULCONNEX
- Monitoring of starting feed chemical tanks thanks to precise level indicators and measuring via radar sensors
- Verification of the chlorine dioxide metering and system output: For consumption levels which can be planned and enhanced system availability
- Configurable alarms and automatically generated reports: For simplified compliance with documentation obligations and to demonstrate correct operation
- Remote monitoring of systems in potentially dangerous environments.
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Municipal drinking water and wastewater treatment
- Industrial process and cooling water
- Disinfection in the food and beverage industry, inlet water treatment
Technical Details
Power supply
- 100-230 V, 50/60 Hz
Inputs
- 4 analogue inputs (0/4-20 mA)
- Water flow
- Control variable
- Acid level
- Chlorite level
- 4 digital inputs
- Contact water meter 0.25-20 Hz
- Pause
- Alternative metering
- External fault
Outputs
- 1 operating signal relay
- 1 alarm signal relay
- 1 warning signal relay
- Mains output for control of the bypass pump
- 2 freely configurable analogue outputs (0/4-20 mA)
Operating substances
- 7.5% sodium chlorite, purity according to EN 938
- 9% hydrochloric acid, purity according to EN 939
- Particle-free water
Degree of protection
- IP 65
Bus communication options
- Modbus TCP / DULCONNEX
- Modbus RTU / DULCONNEX
- Profibus DULCONNEX
- Profinet DULCONNEX
Technical Data
Type | Chlorine dioxide metering rate (min.…max./hour, min./day)* | Max. operating pressure** | Operating temperature | Suction-side connector dimension of calibration vessels | Dimensions of the bypass connector | ||
|---|---|---|---|---|---|---|---|
g/h | g/d | bar | °C | Acid | Chlorite | DN | |
* The metering figures relate to 5 or 2 bar back pressure and an ambient temperature of 20 °C. The minimum capacity/hour is based on the fact that when the system is operating at below 5 % of the nominal capacity, continuous metering is no longer possible due to the fact that the metering pumps then have a low pumping frequency. The reactor contents should be changed at least twice daily with systems that do not work continuously. Therefore, do not operate the system below the stated minimum capacity/day. | |||||||
** at an ambient temperature of 35 °C | |||||||
CDVd 45 | 2.5…45 | 16 | 8 | 10…40 | 6x4 | 6x4 | 25 |
CDVd 120 | 6…120 | 40 | 8 | 10…40 | 6x4 | 6x4 | 25 |
CDVd 240 | 12…240 | 80 | 8 | 10…40 | 8x5 | 8x5 | 25 |
CDVd 600 | 30…600 | 140 | 8 | 15…40 | 12x9 | 12x9 | 25 |
CDVd 2000 | 100…2000 | 468 | 5 | 15…40 | Pressure hose nozzle d16 | Pressure hose nozzle d16 | 40 |
Type | Dimensions H x W x D* | Weight | Supply voltage 230 V** | Supply voltage 115 V** | Power consumption without bypass pump | Power consumption with bypass pump | HCl (9%)*** | NaClO2 (7.5 %)*** |
|---|---|---|---|---|---|---|---|---|
mm | kg | A | A | W | W | l/h | l/h | |
* including main system, pre-dilution and rinse valve, without bypass pump and water feed section | ||||||||
** 230 V figures with bypass pump, 115 V figures without bypass pump | ||||||||
*** Sodium chlorite (NaClO2) 7.5 %, purity in accordance with EN 938, hydrochloric acid 9%, purity in accordance with EN 939. The chemical consumption may vary depending on the temperature. | ||||||||
CDVd 45 | 1,300 x 1,000 x 250 | 55 | 3.8 | 1.6 | 100 | 630 | 1.1 | 1.1 |
CDVd 120 | 1,300 x 1,000 x 250 | 55 | 3.9 | 1.6 | 110 | 640 | 2.9 | 2.9 |
CDVd 240 | 1,300 x 1,000 x 250 | 59 | 3.9 | 1.8 | 120 | 650 | 5.7 | 5.7 |
CDVd 600 | 1,525 x 1,160 x 253 | 84 | 4.0 | 1.9 | 220 | 750 | 14.3 | 14.3 |
CDVd 2000 | 2,000 x 1,320 x 290 | 129 | - | 2.6 | 300 | - | 47.6 | 47.6 |
Ambient conditions:
| Permissible relative air humidity (non-condensing) | max. 85% rel. |
| Permissible ambient temperature | 40 °C |
| Permissible temperature of chemicals | 10 … 35 °C |
| Storage and transport temperature | -10 … +40 °C |
| Degree of protection | IP 65 |
Downloads for Chlorine Dioxide System Bello Zon CDVd
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
Chlorine dioxide system Bello Zon CDVd is for the treatment of medium to large volumes of water with diluted chemicals.
The CDVd chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system is very user-friendly. The system control features intuitive menu navigation and ensures precise chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary production. The special reactor design produces chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary safely and easily. You benefit from maximum yield with minimal chemical consumption and maximum safety. Communication via common bus systems and our DULCOnneX Platform meets all requirements for tomorrow’s Industry 4.0 standards.
Furthermore, in terms of construction and operation, the system meets all requirements of DVGW Worksheets W 224 and W 624 and is intended for use with diluted chemicals: Bello Zon chlorite (7.5% NaClO2) and acid (9% HCl). The liquid levels of the input chemicals can be displayed and monitored either using external liquid level sensors or via the patent-pending adaptive level monitoring system. CDVd is validated in accordance with the current DIN EN 18087:2026-03 standard.
Your benefits
- Highest operating safety and purity of the ClO2 produced
- Communication interfaces via bus systems and DULCONNEX
- Monitoring of starting feed chemical tanks thanks to precise level indicators and measuring via radar sensors
- Verification of the chlorine dioxide metering and system output: For consumption levels which can be planned and enhanced system availability
- Configurable alarms and automatically generated reports: For simplified compliance with documentation obligations and to demonstrate correct operation
- Remote monitoring of systems in potentially dangerous environments.
Application
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Municipal drinking water and wastewater treatment
- Industrial process and cooling water
- Disinfection in the food and beverage industry, inlet water treatment
Technical Data
Technical Details
Power supply
- 100-230 V, 50/60 Hz
Inputs
- 4 analogue inputs (0/4-20 mA)
- Water flow
- Control variable
- Acid level
- Chlorite level
- 4 digital inputs
- Contact water meter 0.25-20 Hz
- Pause
- Alternative metering
- External fault
Outputs
- 1 operating signal relay
- 1 alarm signal relay
- 1 warning signal relay
- Mains output for control of the bypass pump
- 2 freely configurable analogue outputs (0/4-20 mA)
Operating substances
- 7.5% sodium chlorite, purity according to EN 938
- 9% hydrochloric acid, purity according to EN 939
- Particle-free water
Degree of protection
- IP 65
Bus communication options
- Modbus TCP / DULCONNEX
- Modbus RTU / DULCONNEX
- Profibus DULCONNEX
- Profinet DULCONNEX
Technical Data
Type | Chlorine dioxide metering rate (min.…max./hour, min./day)* | Max. operating pressure** | Operating temperature | Suction-side connector dimension of calibration vessels | Dimensions of the bypass connector | ||
|---|---|---|---|---|---|---|---|
g/h | g/d | bar | °C | Acid | Chlorite | DN | |
* The metering figures relate to 5 or 2 bar back pressure and an ambient temperature of 20 °C. The minimum capacity/hour is based on the fact that when the system is operating at below 5 % of the nominal capacity, continuous metering is no longer possible due to the fact that the metering pumps then have a low pumping frequency. The reactor contents should be changed at least twice daily with systems that do not work continuously. Therefore, do not operate the system below the stated minimum capacity/day. | |||||||
** at an ambient temperature of 35 °C | |||||||
CDVd 45 | 2.5…45 | 16 | 8 | 10…40 | 6x4 | 6x4 | 25 |
CDVd 120 | 6…120 | 40 | 8 | 10…40 | 6x4 | 6x4 | 25 |
CDVd 240 | 12…240 | 80 | 8 | 10…40 | 8x5 | 8x5 | 25 |
CDVd 600 | 30…600 | 140 | 8 | 15…40 | 12x9 | 12x9 | 25 |
CDVd 2000 | 100…2000 | 468 | 5 | 15…40 | Pressure hose nozzle d16 | Pressure hose nozzle d16 | 40 |
Type | Dimensions H x W x D* | Weight | Supply voltage 230 V** | Supply voltage 115 V** | Power consumption without bypass pump | Power consumption with bypass pump | HCl (9%)*** | NaClO2 (7.5 %)*** |
|---|---|---|---|---|---|---|---|---|
mm | kg | A | A | W | W | l/h | l/h | |
* including main system, pre-dilution and rinse valve, without bypass pump and water feed section | ||||||||
** 230 V figures with bypass pump, 115 V figures without bypass pump | ||||||||
*** Sodium chlorite (NaClO2) 7.5 %, purity in accordance with EN 938, hydrochloric acid 9%, purity in accordance with EN 939. The chemical consumption may vary depending on the temperature. | ||||||||
CDVd 45 | 1,300 x 1,000 x 250 | 55 | 3.8 | 1.6 | 100 | 630 | 1.1 | 1.1 |
CDVd 120 | 1,300 x 1,000 x 250 | 55 | 3.9 | 1.6 | 110 | 640 | 2.9 | 2.9 |
CDVd 240 | 1,300 x 1,000 x 250 | 59 | 3.9 | 1.8 | 120 | 650 | 5.7 | 5.7 |
CDVd 600 | 1,525 x 1,160 x 253 | 84 | 4.0 | 1.9 | 220 | 750 | 14.3 | 14.3 |
CDVd 2000 | 2,000 x 1,320 x 290 | 129 | - | 2.6 | 300 | - | 47.6 | 47.6 |
Ambient conditions:
| Permissible relative air humidity (non-condensing) | max. 85% rel. |
| Permissible ambient temperature | 40 °C |
| Permissible temperature of chemicals | 10 … 35 °C |
| Storage and transport temperature | -10 … +40 °C |
| Degree of protection | IP 65 |